PULSE BURNERS DEVICES



Device lounging impulse  
Device fiery impulse (hereinafter, ULTRASOUND) are intended for ignition bit high-pressure sodium lamps type Dnata and metal-halide discharge lamps of high pressure type the talking machine. These devices differ from many similar domestic products of high temperature stability voltage response, stability of pulse amplitude, symmetric work in both supply network (one pulse on each half cycle).

 

dimension

Designation of drawings mm mm h, mm
674 711.000 85 37.5 32
674 711.000–01 85 37.5 32
674 711.000–02 100 46 35

depending on THE power of lamps developed 3 modification of the ULTRASOUND examination:

Type (68 2)  Design document Rated power, P, W Mass, g
(no more than)
Dnata DRI
ULTRASOUND-AND-Dnata/DRI-70/35-001 674 711.000 70 35 175
ULTRASOUND-AND-Dnata/DRI-400/400-002 674 711.000–01 100÷400 70÷400 175
ULTRASOUND-AND-Dnata/DRI-1000/1000-003 674 711.000–02 600÷1000 600÷1000 225

 Field of application:

  1. ULTRASOUND-AND-Dnata/DRI-70/35-001-for the ignition of Dnata 70 Watts of power and talking machine with a capacity of 35 W;
  2. ULTRASOUND-AND-Dnata/DRI-400/400-002-for the ignition of Dnata with the capacity from 100 up to 400 W and talking machine with the capacity from 70 to 400 W; 
  3. ULTRASOUND-AND-Dnata/DRI-1000/1000-003 - for the ignition of Dnata with the capacity from 100 up to 1000 Watts of power and talking machine with the capacity from 70 to 1000 Watts.

the design of ULTRASOUND - built - in. Climatic modification - 2 according to GOST 15150-69.

the Main technical characteristics of ULTRASOUND are given in table 1.

Table 1 - Main technical specifications of ULTRASOUND.

Settings ULTRASOUND-AND-Dnata/DRI-70/35-001 ULTRASOUND-AND-Dnata/DRI-400/400-002 ULTRASOUND-AND-Dnata/DRI-1000/1000-003
the mains Voltage with frequency of 50 (60) Hz, v 220 +- 22 220 +- 22 220 +- 22
Voltage, V 170 - 195 170 - 195 170 - 195
pulse Amplitude, Kv 1,8 - 2,3 3,5 - 5,0 3,5 - 5,0
Duration of  the pulse, the iss: at the level of, Kv 0,95 +- 0,05/1,62 0,95 +- 0,05/2,52 0,95 +- 0,05/2,52
the Number of pulses for the period of the mains voltage, not less than, pcs. 2 - 6 2 - 6 2 - 6
the Maximum length of the wires connecting ballast choke with lamp, m 10 10 10
the Maximum capacity of between conductors wire (cable) , not more, Pf 100 100 100
Rated load current, AND 1,0 5,0 10,6
Phase location pulses in the range of degrees al. 60-90/240-70 60-90.240-270 60-90/240-270
product Weight, not more than, kg 0,175 0,175 0,225
the Range of temperatures of exploitation, 0 from minus 40 up to 70
Minimum operating time, h >= 1800

the Functional scheme of connection ULTRASOUND

1 - Machine any control gear (PRA)
2 - the Device pulse kindles (ULTRASOUND examination)
3 - Lamp Dnata/DRI

the Capacity of the lead wire from the lamp to the ULTRASOUND examination should not exceed 100 Pf. 

ULTRASOUND .

the Opportunity to work in ULTRASOUND in the modes and conditions different from those specified in THE, shall be agreed with the developer of THAT.

Warranty period - 18 months from the date of input of ULTRASOUND in the operation.

the Average service life of 10 years.